Cavity | T-2A |
Series | 2 |
Capacity | 120 L/min. |
Factory Pressure Settings Established at | 15 L/min. |
Maximum Operating Pressure | 350 bar |
Control Pilot Flow | 0,16 - 0,41 L/min. |
Pressure Ramp Up Time | 200 - 400 ms |
Response Time - Typical | 2 ms |
Adjustment - No. of CW Turns from Min. to Max. setting | 4.5 |
Valve Hex Size | 28,6 mm |
Valve Installation Torque | 61 - 68 Nm |
Adjustment Screw Internal Hex Size | 4 mm |
Locknut Hex Size | 15 mm |
Locknut Torque | 9 - 10 Nm |